header_template A.jpg (18719 bytes) small.GIF (3857 bytes) banner-addition.gif (4207 bytes)

Downhole Memory Flowmeter

The SFM-200 memory flowmeter provides downhole measurement of flow, borehole temperature, and CCL.

The SFM-200 is utilized for various production logging (PL) and downhole evaluation applications such as locating leaks, flow / injection profiles, detecting non-performing perforations, locating fluid entry zones, detecting channels, etc.  If more precise depth correlation and fluid identification are required, additional Micro-Smart PLT modules such as the SGM-200 Downhole Memory Gamma Logger (gamma ray, borehole temperature, CCL and fluid capacitance) and SP-2000 Downhole Memory Gauge (pressure) are run in combination.  A slickline depth recorder can be used to monitor and store time / depth data.

Have the confidence that "You Know The Flow" with the SFM-200.  The rugged flowmeter design enables the operator to reliably record quality spinner data in the worst well conditions.  Low flow rate wells, in many cases, can be logged successfully, due to the low fluid velocity threshold and high count rate.

A sensitive, high resolution, platinum RTD temperature sensor detects temperature anomalies.  Large memory capacity is adequate for long duration logging projects.

The SFM-200 is easy to program with or without the use of a compatible computer.   With the use of our simple, menu driven software, you can retrieve and report the log data (using a compatible computer and printer).

If the customer requires standard API log prints, Micro-Smart Systems can generate the logs in our Houston office or provide the user with the required software programs and training.   Complete PL analysis can also be provided upon request.

 

Micro-Smart Systems is the SMART choice for cutting-edge technology and superior customer support. We can save you time, money, and help you keep your customers satisfied.

Advantages:

Some advantages of utilizing this tool are :

  • Cost savings
    - less equipment and personnel required
    - less time required for transport and rigging
  • can monitor low flow rates
  • improved data quality
    - memory tool eliminates noise problems associated with electric-line
  • more reliable data acquisition
    - reliable battery power and dual EEPROM tool memory eliminates potential problems with data transmission to surface unit via electric-line and power failures (surface equipment and electric-line shorts)

SMART Features:

Technological features of the SFM-200 are:

  • Tool stores time, bi-directional flow, borehole temperature, and CCL information
  • Dual EEPROM Memory
  • Large memory capacity
  • Tool performs internal tests and delivers audible signal to confirm operation
  • Multiple-run data storage capability
  • Switch selectable programming
  • Custom computer programming
    - up to 15 time periods
    - specify time interval and sampling rate

"YOU KNOW THE FLOW"

SPECIFICATIONS:

Memory Capacity :  48,000 data sets (main memory) Temperature : Resolution   .04° F
                                2,000 data sets (backup memory)                       Accuracy   ± 2° F
Sampling Intervals : 1.875 seconds to 64 minutes Spinner : Resolution   12 pulses/revolution
                                 (in binary multiples)                Minimum Fluid Velocity  7.8 ft/min  
Operating Temp. :  32° F to 325° F    (0° C to 160° C)                 Impeller diameter  1 inch
Max. External Pressure : 15,000 psi (102,000 KPA) Length : 11.2 ft. (3.4 m) including  battery pack & centralizer
Power : 13.5v (9 ‘c’ cell Alkaline) Diameter : 1.6"   (40.6 mm)
            14.4v (4 ‘c’ cell Lithium) Collar Sensor Velocity : 2-7/8" tubing - 25 ft/min    
Weight : 32 lbs. (14.5 Kg)                                    3-1/2" tubing - 50 ft/min 
                                   Collar samples accurate to 3-1/2" tubing
                                   Maximum wireline speed 200 ft/min

 

Micro-SMART Systems, Inc.
5355 Anderson Road
Houston, Texas 77053

phone : 713.433.2277
fax : 713.433.2443